G5Twin Refrigerant Recovery Machine
Ultra-Fast, High Volume Refrigerant RecoveryThe G5 Twin is the smallest and lightest recovery machine capable of handling the tough demands of industrial/commercial refrigerant recovery - no job is too big for this little beast.
![]() |
Features and Benefits
|
- 7-inch 10-blade turbine fan @ 3000 rpm blasts 600 cfm of cooling air over the twin heads and condensers
- Operates up to 50 degrees cooler for maximum reliability and speed even in high ambient conditions
- Recovery Rates of 0.62 lbs./minute vapor and 6.22 lbs./minute of liquid (ARI 740-98 Ratings R22)
Technical Bulletins
Hazards of Using 80% Shut Off Switches (PDF)Why you should use Inline Filter Dryers (PDF)
Protecting Gauges from High Pressure Surges (PDF)
Preventing Voltage Drop thru Extension Cords (PDF)
Product Specifications
| Recovery Rates (lb/min) | ||
|---|---|---|
| R410a | R22 | |
| Push/Pull | 10.21 | 16.62 |
| Direct Liquid | 3.48 | 6.22 |
| 76°F Vapor | 0.66 | 0.62 |
| 104°F Vapor | N/A | 0.42 |
| Dimensions and Power | ||
|---|---|---|
| Length | 13.75 in. | 349 mm |
| Height | 10.3 in. | 262 mm |
| Width | 9.4 in. | 239 mm |
| Weight | 24 lbs. | 11 kgs. |
| Power | 115 VAC, 60 Hz, 10 Amps | |
UL certified to meet or exceed EPA regulations per ARI 740-98.
For use with all class III, IV, and V refrigerants:
R-12, R-134a, R-401c, R-406a, R-500, R-401a, R-409a, R-401b, R-412a, R411a, R-407d, R-22,
R-411b, R-502, R-407c, R-402b, R-408a, R-509, R-407a, R-404a, R-402a, R-507, R-407B, R-410a